Filter by:

669 results:

Result 49 - 72 out of 669

Rugged full metal sensors for use in challenging applications
  • Types: M8 to M30
  • Large sensing ranges: 2 mm to 40 mm
  • Enclosure rating: IP68, IP69K
  • Temperature range: –25 °C to +85 °C
  • Option of rugged housing or housing suitable for the food industry made completely out of stainless steel
  • IO-Link and visual adjustment indicator
  • Resistant against oils, cooling lubricants and cleaning products
Compare now
Select
Safe, easy, flexible Encoders for functional safety
  • Encoders for functional safety technology: SIL2 (IEC 61508), SILCL2 (EN 62061), PL d (EN ISO 13849)
  • Electrical interface: 4.5 V ... 32 V; sine/cosine 1 VPP; 1,024 periods
  • Face mount flange or servo flange, blind hollow shaft or through hollow shaft (assembly options with feather key)
  • Universal cable connection, M23 or M12 male connector, axial or radial
  • Enclosure rating: IP65
  • Operating temperature range: –30°C ... +95°C (depending on type)
Compare now
Select
Powerful measurement of mercury in flue gases
  • Accurate measurement of “total mercury” directly in a thermal converter (patented)
  • Measuring operation without reagents
  • Practically maintenance-free gas sampling using an ejector pump – no moving parts
  • Integrated adjustment cell for automated drift checking
  • Automated adjustment of the entire measuring system with a built-in test gas generator (optional)
  • Completely modular system design
Compare now
Select
The economic standard for use in industrial environments
  • Types: M8 to M30
  • Extended sensing ranges: 1.5 mm to 38 mm
  • Electrical configuration: DC 3-/4-wire, DC 2-wire
  • Enclosure rating: IP67
  • Temperature range: –25 °C to +75 °C
  • Nickel-plated brass housing; plastic sensing face
Compare now
Select
Measure aggressive gases directly and quickly – even in ATEX zones
  • Direct, fast in-situ measurement
  • No gas sampling, no gas transport, no gas conditioning
  • Up to four measurands at the same time, plus process temperature and pressure
  • DOAS evaluation methods
  • Numerous independent measuring ranges with consistent accuracy
  • Automated self-test function (QAL3) without test gases
  • Overpressure encapsulated type for Ex-zone 2
Compare now
Select
For a wide range of detection and measuring tasks – light grid in very compact housing
  • Housing dimensions: 12 mm x 24 mm, detection heights: 100 mm to 2,400 mm
  • Slim and flat housing variants
  • Cross-beam function: Up to 9 beams
  • Short response times due to its own light grid ASIC
  • Detection, classification and measurement functions as well as Smart Tasks
  • Detailed diagnostic information
  • IO-Link COM3 interface
Compare now
Select
Position sensors for C-slot
  • Position sensor for direct mounting in C-slots on pneumatic cylinders and grippers
  • Sensor variants with measuring ranges of 25 mm to 200 mm
  • Analog outputs (for current or voltage), switching output, and IO-Link
  • Mounting on other cylinder types (e.g., round body cylinders) is possible with adapters
Compare now
Select
Easy to install. Easy to operate. The one photoelectric proximity sensor for all applications.
  • The world’s first photoelectric sensor with touchscreen display-enabled sensor with refined user-interface allowing simple operation
  • High performance thanks to a precise laser triangulation system with line scanning
  • Buy one, manage one, inventory one, train one, troubleshoot one, replace one
  • Sturdy design with 316L stainless steel housing and IP69k protection rating
  • MultiMode functions such as speed, standard, and precision mode, foreground and background suppression, and teach options
  • Standardized mounting, pre-configured settings and multiple teach-in options for simple sensor integration
  • Button-free interface with lockout ability
Compare now
Select
The smart solution for challenging detection tasks
  • Response time up to 16 µs
  • Sensing range up to 20 m (through-beam system); up to 1.4 m (proximity system)
  • IP54 enclosure rating
  • OLED display with text display in various languages
  • Stand-alone version with IO-Link
  • Diagnostic functions and Smart Tasks
  • Adjustable hysteresis and continuous threshold adaptation
  • Bus version available
Compare now
Select
For efficient control of combustion and drying processes
  • Dynamic humidity correction
  • Fast in-situ measurement directly in the process
  • Simultaneous determination of up to three gas components, temperature, and pressure
  • No gas sampling and conditioning
  • Gas testable version of measuring probe available
  • Integrated self-test and control functions
Compare now
Select
The reliable sensors in dusty environments and for applications with long sensing range
  • Additional front LED provides information on light reception status
  • Large sensing range with high operating reserve
  • M12 male connector, cable and connection chamber
  • DC and AC/DC voltage supply
  • Operating temperature range from –30 °C to +60 °C
  • Optionally with time delay
Compare now
Select
The safety relay for high ease of use
  • Clever, user-friendly housing functions
  • Thin design with construction widths from 18 mm
  • Fast response times of under 10 ms (depending on the type)
  • Status LEDs and diagnostic interfaces
  • Variants for universal application and for safe series connection with Flexi Loop available
Compare now
Select
Strong performance in rugged metal housing for demanding detection tasks
  • Precise autocollimation optics
  • Light sources: laser, PinPoint LED, infrared light
  • MultiMode function
  • Line-shaped light spot for detecting perforated objects
  • ApplicationSelect mode available
  • IO-Link and BluePilot for parameterization
  • Diagnostic functions via IO-Link
  • Rugged zinc die cast metal housing
Compare now
Select
Highest precision for web width measurement
  • Measurement accuracy: ± 0.3 mm
  • Resolution: 0.1 mm
  • Measuring field: 3,150 mm (in 150 mm steps)
  • Response time: 32 μs (from beam to beam)
  • Interfaces: 3 switching outputs, analog interface, IO-Link, RS-485, PROFINET, EtherCAT® and EtherNet/IP™
  • Operating range: 2,500 mm
  • Interface output: 10 edges with 5 edges and 5 center positions
Compare now
Select
Cylinder sensors with precise switching point for T-slot
  • Can be used in all standard cylinders, linear slides, and grippers using the T-slot and – with the help of adapters – in round rod, tie-rod, and profile cylinders, and cylinders with a dovetail groove
  • Insertion of the sensor into the slot from above makes mounting quick and easy
  • Combined fixing screw (hexagon socket screw and slotted screw)
  • High-temperature variants: temperature-resistant up to 100 °C
  • Very short sensor housing for use in short stroke cylinders
  • Enclosure ratings: IP 67, IP 68, IP 69K
Compare now
Select
The universal IO-Link master with IIoT competence
  • 8 IO-Link ports (M12; 5-pin; A-coded; Class A/B)
  • Current carrying capacity of up to 16 A at max. 4 A per port for US and UA
  • Rugged IP67 housing
  • Operating temperature –30 °C ... +70 °C
  • PROFINET, EtherNet/IP and EtherCAT available
  • REST API, MQTT and OPC UA IIoT protocols can be used
  • Rotary encoding switch for IP addressing
Compare now
Select
Cylindrical photoelectric sensors with foolproof touch-teach for washdown areas
  • IP 69K-rated cylindrical photoelectric sensors in M18 stainless steel housing
  • Resistant to all common cleaning agents and certified by independent institutes
  • Extended temperature range: +85° C (long-term), +100°C / 15 min. (short-term)
  • Touch (smart) teach-in adjustment
  • All sensor materials, including the housing, LED and lens are resistant to chemicals
  • IP 69K and IP 68 according to DIN 40050
  • Laser-etched part numbers
  • Ecolab & JohnsonDiversey certified for chemical resistance
Compare now
Select
Efficient process analysis – even under difficult conditions
  • High selectivity due to high spectral resolution
  • Short response times
  • No calibration required
  • No moving parts: minimal wear and tear
  • No gas sampling or conditioning required
  • Overpressure encapsulated design for ATEX Zone 2
Compare now
Select
The flexible and efficient detection system in one chain
  • Ultra-simple wiring for up to 60 sensors
  • Sequential cycling prevents mutual interference
  • Free arrangement of various sensor technologies
  • Sensors available in different lengths of cable
  • Sensor data evaluation in the system or direct transmission of raw data
  • Process stability thanks to diagnostic function
Compare now
Select
Stay in control with proven FTIR measurement technology
  • Small suitability-tested HF measuring range: 0 ... 3 mg/m³
  • Automatic spectrum adjustment via AutoVAL for reliable measured values
  • Operation via touchscreen
  • Sample gas transport by an ejector without moving parts
  • Suitability-tested according to EN15267
  • Remote control and diagnosis via SOPAS ET software
  • Automatic adjustment of the analyzer
  • Automatic backwashing and filter cleaning of the extraction unit
Compare now
Select
Ultra high speed measurement for linear direct drives
  • Absolute measurement system for linear direct drives
  • Measuring lengths: up to 16,384 mm
  • High traversing speeds: up to 10 m/s
  • Status LED
  • Non-contact measurement system; reading distance to the magnetic tape: up to 0.8 mm
  • Electronic type label
  • ETL70 with one cable technology thanks to the HIPERFACE DSL® interface
  • STL70 with HIPERFACE® interface
Compare now
Select
Easily and reliably detecting double films
  • Sizes: M8 and M12
  • Detection of metallic double films
  • Electrical configuration: DC, 4-conductor
  • Temperature range: −25 °C ... +70 °C
  • Enclosure rating: IP68
  • Detection regardless of the gripper position
  • Teach-in via cable or IO-Link
Compare now
Select
Turns pressure into colors
  • Large display shows system pressure, output states, and switching points
  • Three large function keys, intuitive menu navigation
  • Measuring range for gauge pressure (vacuum and overpressure)
  • Two independently programmable switching outputs, optional analog output
  • Installation on mounting rail, wall or switch panel
  • Variant for leakage monitoring
  • IO-Link
Compare now
Select
Reliable gas flow measurement on flare stacks in petroleum refineries, chemical plants and natural gas processing with SICK ultrasonic gas flow meters.
  • Reliable measurement even at high gas velocities and with changing gas compositions
  • Proprietary measuring range extension for high flow velocities thanks to ASC technology
  • Direct mass flow calculation without additional gas analyzers
  • Intuitive FLOWgateTM software for commissioning, operation and diagnostics
  • I-diagnosticsTM: self monitoring, self testing and predictive maintenance
  • Customized measurement performance thanks to individual evaluation of the application
Compare now
Select

Result 49 - 72 out of 669